Product Center
+
  • 固定紅(hóng)外(wài)測溫儀.jpg
  • 固定紅(hóng)外(wài)測溫儀2.jpg
  • 固定紅(hóng)外(wài)測溫儀3.jpg
  • 固定紅(hóng)外(wài)測溫儀4.jpg

Fixed infrared thermometer

retail price

$ 0

market value

$ 0


Fixed infrared thermometer
Quantity
-
+

stock

10

隐藏域元素占位

  • Product Description
    • Commodity name: Fixed infrared thermometer
    • Commodity ID: 1-6-04

    Fixed infrared thermometer

    Introduction:

    YD type infrared thermometer is a kind of infrared temperature measurement p₽roduct specially used in single crystal furnace, which is developed by our company in com'bination with German technology and according to the field appli cation of semiconductor single crystal silicon. It ha→s the characteristics of fast tracking speed, high sensitivity, no damage to the teεmperature distribution of the measured object, and can measure ♣small targets. Especially for the measurement and control of high temp±erature, fast moving, rotating and other objects. Its reliabilit<y, stability and cost performance have won the reco↔gnition of users.

     

    YD infrared thermometer is a kind of non-contact measuring instrument based o₹n the principle of infrared radiation. It can ente r the special band of infrared radiation energy quantization in the measurement field of view, and♣ convert the phase into electrical signals that can be recognized and use∞d. Because the crystal growth diameter and growth length can be controlled by adjuεsting the rotation speed and pulling speed, stable temperature is an important factor for the unif♦orm growth of silicon crystal rod. YD infrared thermometer solves the problems of qua♠lity control and diameter control in the process of silicon crystal growth. If the ©signal is amplified and linear processed, the closed-loop control can also be carried out. Since §the advent of MT single crystal furnace special infrared thermometer, with its outstanding pe₽rformance, it has been widely used in the single crystal furnace industry.

    Technical parameters:

     

        model     YDseries
        Wavelength range        0.8~1.4um
        Measuring rang     600~2500℃
        target     Ф20~ф10
        measurement accuracy     ±1℅
        Repeatability    It is ± 0.3% of the reading value at 25 ℃
        response time     <1S
        Measure the distance     Standard lens: 0.2 ~ 2m, close range lens¥: 0.1 ~ 0.    
        output signal     0—50Mv/0—100mV
        humidity     ≦85℅RH
        ambient temperature     -18 ~ 60 ℃ with water cooling to 150 ℃